1983 911 sc fan motor issue

sneillyboy

Member
Joined
8 Apr 2013
Messages
5
Hi Guys

wondered if any of you could point me in the right direction ?

Have removed the fan assembly whilst car is away being painted .

Fan didnt work prior to removal so can you tell me how to test unit ?

What should the windings for each fan speed be ?

which of the 4 connections on the plug do what ?

thanks in advance
 
If you post on impactbumpers.com I am sure one of the guys on their will know
Good luck
 
Ive only found the 1984 diagram but i think its the same ..

Pin 4 would be the 12 volt supply
Pin 3 the earth for full speed
Pin 1 and 2 the earth for the slowspeeds .
 

Attachments

  • motor_1_190.jpg
    motor_1_190.jpg
    351 KB · Views: 12,034
Demort said:
Ive only found the 1984 diagram but i think its the same ..

Pin 4 would be the 12 volt supply
Pin 3 the earth for full speed
Pin 1 and 2 the earth for the slowspeeds .

Also spin the fan by hand .. ive seen a few now that are seized .. if so then removeing the fan from the motor in one piece is a pain but if you can its a lot cheaper than an entire fan unit .
 
progress

Thanks Guys

having tested by running 12v to the unit I have discovered that the fan will only run at full speed.

Can someone explain how the unit works that controls the 2 slower speeds ?

Really appreciate all of your help

:bow: [/img]
 
Demort said:
Ive only found the 1984 diagram but i think its the same ..

Pin 4 would be the 12 volt supply
Pin 3 the earth for full speed
Pin 1 and 2 the earth for the slowspeeds .


Sorry .. i missed this when you first replyed :oops:


If you have the fan removed or unplugged then put 12 volts to pin 4 and an earth to pin 3 that will be full speed ..

If you move the earth from pin 3 to pin2 then it will be one of the slow speeds with the earth on pin 1 being the other slow speed.

If neither slow speed works then its the resistor in the fan unit thats faulty .. if all works then its the switch or the wiring to the switch thats faulty .
 
really need to know how to test/ repair the resistor set in the plug connection ?
 

Attachments

  • img_0025_170.jpg
    img_0025_170.jpg
    1.6 MB · Views: 11,706
  • img_0026_119.jpg
    img_0026_119.jpg
    1.5 MB · Views: 11,706
Aghh i answered your PM without seeing this .. the crimps look the most obvious place to go high resistance .

I think you have 2 contacts there that as they get hot will switch it to full speed .. the diagram would seem to indicate this so if you get full speed on pin 1 or 2 when given an earth then thats the fault .
 
Thanks guys

so it would appear that the crimped terminations between the resistors and the 4 terminals suffer from corrosion !

Cleaned them up and ran solder into each one and result ! :) :D :D

many thanks for ur help :worship: